SI Units for PostgreSQL
Christoph Berg cb@df7cb.de
postgresql-unit implements a PostgreSQL datatype for
SI units, plus byte.
The eight base units can be combined to arbitrarily complex derived units using
operators defined in the PostgreSQL type system. SI and
IEC binary prefixes are
used for input and output, and quantities can be converted to arbitrary scale.
Unit and prefix definitions are retrieved from database tables, and new
definitions can be added at run time. The extension comes with over 2500 units
and over 100 prefixes found in the definitions.units file
in GNU Units.
Requires PostgreSQL 9.5 or later (uses HASH_BLOBS), flex, and bison 3 (the
pre-built grammar files are used if only bison 2 is available).
Changelog
Features
- Base types: meter (m), kilogram (kg), second (s), ampere (A), kelvin (K),
mole (mol), candela (cd), byte (B)
- derived units coherent with SI: radian (rad), steradian (sr), hertz (Hz),
newton (N), pascal (Pa), joule (J), watt (W), coulomb (C), volt (V), farad
(F), ohm (Ω), siemens (S), weber (Wb), tesla (T), henry (H), degree Celsius
(°C, support limited), lumen (lm), lux (lx), becquerel (Bq), gray (Gy),
sievert (Sv), katal (kat)
- non-coherent units: minute (min), hour(h), day(d), hectare (ha), litre (l),
tonne (t), bar, astronomical unit (au)
- United States customary units: inch (in), foot (ft), yard (yd), mile (mi),
ounce (oz), pound (lb)
- about 2400 other units imported from GNU Units (including some humorous ones)
- prefix multiples: da, h, k, M, G, T, P, E, Z, Y, R, Q
- prefix fractions: d, c, m, μ, n, p, f, a, z, y, r, q
- IEC binary prefix multiples: Ki, Mi, Gi, Ti, Pi, Ei, Zi, Yi, Ri, Qi
- other prefixes imported from GNU Units
- operators: *+, -, *, /, ^**, conversion to arbitrary scale (*@, @@**)
- aggregate functions
- range type
Examples
# CREATE extension unit;
CREATE EXTENSION
# SELECT '800 m'::unit + '500 m' AS length;
length
--------
1.3 km
# SELECT '120 km/h'::unit AS speed;
speed
----------------------
33.3333333333333 m/s
# SELECT '9.81 N'::unit / 'kg' AS gravity;
gravity
------------
9.81 m/s^2
# SELECT '1 kilosecond'::unit AS time;
time
------------
00:16:40 s
# SELECT '2 MB/min'::unit @ 'GB/d' AS traffic;
traffic
-----------
2.88 GB/d
# SELECT '1 hl'::unit @ '0.5 l' AS bottles_of_beer;
bottles_of_beer
-----------------
200 * 0.5 l
# SET unit.byte_output_iec = on;
# SELECT '4 TB'::unit AS disk_sold_as_4tb;
disk_sold_as_4tb
----------------------
3.63797880709171 TiB
# SELECT '500 mi'::unit AS walk_500_miles;
walk_500_miles
----------------
804.672 km
# SELECT unitrange('earthradius_polar', 'earthradius_equatorial') AS earthradius;
earthradius
-----------------------------------------
["6.35675174834046 Mm","6.37813649 Mm")
# SET extra_float_digits = -12;
# SELECT 'earthmass'::unit as earth;
earth
─────────
5.97 Rg
Installation
To compile from source, install the PostgreSQL server headers, flex, and
bison. Example on Debian:
sudo apt-get install build-essential postgresql-server-dev-10 flex bison
make PG_CONFIG=/usr/lib/postgresql/10/bin/pg_config
sudo make install PG_CONFIG=/usr/lib/postgresql/10/bin/pg_config
Config
unit.byte_output_iec:
Set to on to format byte quantities using IEC binary prefixes (Ki, Mi, ...)
on output by default. (Default: off)
unit.output_base_units:
Set to on to format values using only base types without prefixes.
(Default: off)
unit.output_superscript:
Set to on to output unit exponents using Unicode superscripts.
(Default: off)
unit.time_output_custom:
Set to on to output time unit values greater or equal to 60 s using minutes,
hours, days, and julianyears instead of seconds with SI prefixes.
(Default: on)
Internal Representation
Internally, unit datums are a 16-byte struct consisting of a double precision
floating point number for the unit value, and an array of 8 signed character
values to store the exponents of the base units for the unit dimension.
typedef struct Unit {
double value;
signed char units[N_UNITS];
} Unit;
All operators and functions operate with that base-units-only format.
Conversion from and to other unit representations is done on input, output, and
using the @ operator only.
This is also the format used in binary mode in the PostgreSQL wire protocol.
Prefixes and Units Lookup Tables
Prefixes are defined in the table unit_prefixes:
CREATE TABLE unit_prefixes (
prefix varchar(32) PRIMARY KEY,
factor double precision NOT NULL,
definition text, -- original definition, informational
dump boolean DEFAULT true
);
Units are defined in the table unit_units:
CREATE TABLE unit_units (
name varchar(32) PRIMARY KEY,
unit unit NOT NULL,
shift double precision, -- NULL means 0.0 here
definition text, -- original definition, informational
dump boolean DEFAULT true
);
Whenever the unit input lexer encounters a unit name, it queries the
unit_units table to see if the definition is found. If no match is found, the
unit_prefixes and unit_units tables are cross-joined to see if the
concatenation of prefix and unit name matches. At this point, an error is
thrown if the prefix-unit combination is ambiguous, e.g. for "dat" which is
either a dekatonne (da-t) or a deciatmosphere (d-at). If no match is found, and
the unit name is ending with 's' (e.g. "kilometers" or "lbs"), the two lookup
steps are repeated with the trailing 's' removed.
If the unit definition could be resolved, the result is stored in a
backend-local hash table to speed up the next lookup. (The function
unit_is_hashed() reports if a given unit name is already cached. The function
unit_reset() clears the hash table. Use it if unit definitions are changed.)
The definition column is only provided for information on how the unit was
originally defined.
GNU Units
On installation, the prefixes and units definitions tables are populated with
data imported from the definitions.units file found in the GNU Units tool.
Notable omissions are currency units (we don't have a base type for them, and
exchange rates aren't static anyway), and non-linear units such as dBm based
on dB and other conversions based on functions and lookup tables.
The definitions.units file is an interesting read on its
own due to extensive comments explaining the history and origin of the units
covered.
The unit_load() function can be used to reload the unit_prefixes.data and
unit_units.data files from disk. Extension upgrades use it to load newly
added or changed definitions, but it is also user-callable. User-defined
entries are preserved.
User-Defined Prefixes and Units
To create custom prefixes and units, insert new rows into the tables:
# SELECT '1 foobar'::unit;
ERROR: unit "foobar" is not known
# INSERT INTO unit_prefixes VALUES ('foo', 42);
INSERT 0 1
# SELECT '1 foobar'::unit;
unit
---------
4.2 MPa
# INSERT INTO unit_units VALUES ('legobrick', '9.6 mm');
# SELECT '1 m'::unit @ 'legobricks' AS one_meter;
one_meter
-----------------------------
104.166666666667 legobricks
Note: If user-defined (or built-in) units are changed by updating the tables,
call unit_reset() to clear the hash table that caches the lookup result.
Otherwise, sessions that have already used the unit will continue to use the
old definition.
Input Syntax
Unit values allow a fairly complex expression syntax on input.
expr expr denotes multiplication
- operators + - * /
- exponentiation:
expr^integer or Unicode superscripts: expr⁺⁻⁰¹²³⁴⁵⁶⁷⁸⁹
- parentheses ()
- multiplication binds tighter than division such that
kg/s^2*A and kg/s^2 A
can be written without parentheses
N|M denotes a numeric fraction, e.g. 3|4
- use
hh:mm:ss[.sss] for time values, e.g. 10:05:30 s
- functions:
sqrt(unit), exp(x), ln(x), log2(x), asin(x), tan(x)
Note: This covers the unit input parser for expressions like
'1|2 m / h'::unit. PostgreSQL operators on type unit values are a separate
layer; PostgreSQL's operator precedence applies there.
Output Syntax
Internally, unit values are always stored in base units. On output, values are
generally formatted as +-N x*y/z*w where +-N is a floating point number,
and x*y/z*w is a set of base units with exponents. Specific combinations of
base units are formatted differently (unless unit.output_base_units is set):
Time (seconds) is formatted as N commonyear + hh:mm:ss.sss s if the
value is at least one minute, and unit.time_output_custom is set (the
default). Otherwise, time is formatted as by the next rules.
If the set of base units matches one of the following well-known derived units,
output is formatted using SI prefixes and that unit.
| Unit |
Name |
Dimension |
Units |
Base Units |
| Hz |
hertz |
frequency |
|
s^-1 |
| N |
newton |
force, weight |
|
kg·m·s^-2 |
| Pa |
pascal |
pressure, stress |
N/m^2 |
kg·m^-1·s^-2 |
| J |
joule |
energy, work, heat |
N·m |
kg·m^2·s^-2 |
| W |
watt |
power, radiant flux |
J/s |
kg·m^2·s^-3 |
| C |
coulomb |
electric charge |
|
s·A |
| V |
volt |
voltage |
W/A |
kg·m^2·s^-3·A^-1 |
| F |
farad |
electric capacitance |
C/V |
kg^-1·m^-2·s^4·A^2 |
| Ω |
ohm |
electric resistance, impedance |
V/A |
kg·m^2·s^-3·A^-2 |
| S |
siemens |
electrical conductance |
A/V |
kg^-1·m^-2·s^3·A^2 |
| Wb |
weber |
magnetic flux |
V·s |
kg·m^2·s^-2·A^-1 |
| T |
tesla |
magnetic flux density |
Wb/m^2 |
kg·s^-2·A^-1 |
| H |
henry |
inductance |
Wb/A |
kg·m^2·s^-2·A^-2 |
| lx |
lux |
illuminance |
lm/m^2 |
m^-2·cd |
| Gy |
gray |
absorbed dose (of ionizing radiation) |
J/kg |
m^2·s^-2 |
| kat |
katal |
catalytic activity |
|
mol·s^-1 |
Note: this does not preserve the input dimension, e.g. N m (torque) is
converted to J (energy).
If the dimension numerator is exactly a base unit (with exponent 1), output
is formatted using SI prefixes and that unit, followed by the denominator
units, if any.
- If that unit is Bytes, and
unit.byte_output_iec is set, IEC prefixes are
used instead.
Shifted Units
The unit_units.shift column is used for implementing units where 0 is not
absolute zero in base units, i.e. most commonly for temperature units (°C, °F).
Shifted units are often used in ambiguous contexts, the intended meaning
depending on if an absolute value, or a difference between values is requested.
If 20 °C - 15 °C is requested, the answer 5 K is clearly correct, but less
so 5 °C, because that is actually 278.15 K. On the other hand, some
thermodynamic units are defined based on °C, such as
celsiusheatunit = cal lb (degC) / gram K where no offset is desired.
This module resolves the ambiguity by only applying the shift offset in
number name (and plain name) expressions such as 5 °F. In all other
contexts, shifted units behave just like a unit defined on based units without
a shift.
# SELECT '5 °F'::unit, '5 * °F'::unit, '5 °F'::unit @ '°C' AS to_celsius, '5 °F'::unit @ '1 * °C' AS celsius_increments;
unit | unit | to_celsius | celsius_increments
----------+--------------------+----------------------+--------------------
258.15 K | 2.77777777777778 K | -14.9999999999999 °C | 258.15 * 1 * °C
PostgreSQL Operators and Functions
The unit extension provides the following objects: