MOD16 Evapotranspiration Model
The MOD16 terrestrial evapotranspiration algorithm calculates three surface fluxes of latent heat (water vapor):
- Evaporation from bare soil surfaces
- Evaporation from wet canopy surfaces
- Transpiration from terrestrial vegetation
This Python implementation can be used to:
- Calibrate MOD16 on observed latent heat fluxes, such as from eddy covariance flux towers
- Run MOD16 for arbitrary spatial domains (arrays) over arbitrary time steps
- Calculate the sensitivity of the model to its parameters, based on observed latent heat fluxes
The version of MOD16 in this Python implementation is a draft release of the algorithm that will be used in MODIS Collection 7 and in VIIRS Collection 2. There are substantial changes from MODIS MOD16 Collection 6.1, which are detailed in the module documentation (under "NOTES").
Installation and Tests
It's recommended that you install the package in "editable" mode using pip. From the root of the repository:
pip install -e .
If you want to install additional libraries needed for calibrating MOD16:
pip install -e .[calibration]
Tests can be run by:
python tests/tests.py
The MOD16 library depends on the MOD17 library.
Documentation
You can read the online module documentation here. Below, an overview of the MOD16 algorithm is provided.
Example use cases can be found in the notebooks folder; in particular:
Citation
If using this model, please cite our most recent peer-reviewed publication:
Algorithm Details
As described by K. Arthur Endsley, September 2023
Surface Energy Balance
For a large, homogeneous surface, net radiation intercepted by the earth's surface, $R$, can be partitioned into fluxes of sensible heat ($H$), latent heat ($\lambda E$), ground heat ($G$), and the change in heat storage ($\Delta S$):
$$
R = H + \lambda E + G + \Delta S
$$
In this expression, positive values of $R$ represent energy provided to the earth’s surface while positive values of $H$, $\lambda E$, $G$, and $\Delta S$ represent energy removed from the surface. Generally, these quantities are positive during the daytime and zero or negative at night.
Latent heat, or heat that has been used to vaporize water, is the quantity of interest in the MOD16 algorithm and it can generally be described in terms:
$$
\lambda E \propto \frac{A + (\rho, C_p)(e_{\text{sat}} - e)}{\gamma(1 + r_S)}
$$
The individual terms are described in the sections below, but the general idea is that the latent heat flux:
- Increases with incident radiation from the sun and the surrounding environment, $A$
- Increases with the air's capacity to store water vapor, $e_{\text{sat}} - e$
- Increases with the heat storage capacity of air, $\rho\times C_p$
- Decreases with increasing surface resistance, $r_S$ (resistance to water reaching the evaporative front)
The flux of latent heat is also termed evapotranspiration (ET) because it includes both evaporated water and transpired water vapor fluxes. Most discussions of modeling ET begin with a version of the equation above, which gets complicated quickly when we try to calculate ET over large areas using weather data. As such, our description of the MOD16 ET model is instead procedural, to aid implementation.
The MOD16 Algorithm
The evaporation of water is like a commercial transaction in which a wet surface sells water vapour to its environment in exchange for heat...The environment can supply heat by solar radiation, by turbulent transfer from the atmosphere, or by conduction from the soil.
MOD16 is based on the Penman-Monteith (PM) approach to calculating evapotranspiration (ET). The central idea of the PM approach is that it combines energy conservation and the saturation vapor pressure of the air to determine: 1) How much energy is available to vaporize water; and 2) When to stop vaporizing water (when the air is saturated).
Evapotranspiration (ET) is the sum of three components (three sources of latent heat): transpiration, evaporation from wet canopy surfaces, and evaporation from bare soil surfaces. The MOD16 algorithm calculates separate daytime (i.e., sun in the sky) and nighttime quantities for each of these components. We can understand the MOD16 algorithm as a series of steps to calculate each component wherein the input drivers are partitioned into daytime and nighttime values, starting with the calculation of the net radiation received by a surface.
Throughout, unless otherwise specified: temperature is given in degrees Kelvin; pressure is given in Pascals (Pa); resistance is given in seconds per meter.
Net Radiation Available
The net radiation available to vaporize water, $A$, is the sum of down-welling, short-wave radiation intercepted from the sun, $R_{S\downarrow}$, and net long-wave radiation, $R_L$, from the earth and atmosphere:
$$
A = (1-\alpha)R_{S\downarrow} + R_L
$$
Where $\alpha$ is the short-wave albedo (under "black-sky" conditions), i.e., the fraction of down-welling, short-wave radiation that is not absorbed by the earth's surface. MOD16 used to calculate the latter term using the emissivity of the earth's surface; as of MODIS Collection 6.1, we instead use the net long-wave radiation from a land model. Because the sun is the only source of short-wave radiation in this system, at nighttime, $R_{S\downarrow} = 0$ and the only source of energy is $R_L$.
The three components of ET imply there are two surface sources of water vapor: the vegetation canopy (leaf surfaces) and bare soil. Therefore, the next step is to calculate the net radiation received by each of these surfaces. The net radiation received by the soil is a balance between incoming radiation, $A$, and the ground heat flux, $G$, modulated by the fraction of vegetation cover, $F_C$; i.e., if the ground is completed covered by vegetation ($F_C = 1.0$), then there is no ground heat flux. In MOD16, we use the fraction of photosynthetically active radiation (fPAR), a measure of the fraction of ground area covered by photosynthetic vegetation, as our measure of $F_C$. Therefore, net radiation received by the soil surface is calculated:
$$
A_{\text{soil}} = (1 - F_C)\times (A - G)
$$
Ground heat flux is calculated based on the surface energy balance and a pre-determined (calibrated) minimum temperature constraint, $T_{\text{min,close}}$, which represents the temperature below which plant stomata are assumed to be completely closed. If the mean annual temperature is between $T_{\text{min,close}}$ and 25 degrees C, and if the contrast between daytime and nighttime air temperatures is greater than 5 degrees C, then ground heat flux is calculated based on an empirical relationship determined using field data and spectral vegetation indices (Jacobsen and Hansen 1999; Mu et al. 2011):
$$
G = 4.73 T - 20.87 \quad\mathrm{iff}\quad T_{\text{min,close}}
\le T_{\text{annual}} < 25 \quad\text{and}\quad T_{\text{day}} - T_{\text{night}} \ge 5
$$
Otherwise, ground heat flux is zero. When non-zero (as above), we additionally constrain $G$ so that it is no greater than 39% of the net radiation to the land surface:
$$
G = 0.39 A \quad\mathrm{iff}\quad G > 0.39 |A|
$$
Again, $G$ and $A_{\text{soil}}$ are calculated separately for daytime and nighttime input values. When calculating daytime $G$, if the daytime $G$ would be greater than $A$, then $G = A$. When calculating nighttime $G$, if nighttime $A$ (equivalent to $R_L$) minus $G$ would be less than -0.5 times daytime $A$, then $G$ is taken to be equal to nighttime $A$ plus half of daytime $A$.
Vapor Pressure, Humidity, and Saturated Fraction
There are a number of quantities used in calculating all three components that must be calculated separately for daytime and nighttime inputs.
The saturation vapor pressure (SVP) is calculated based on the August-Roche-Magnus equation, also used by the Food and Agriculture Organization (FAO) (Equation 13):
$$
\text{SVP} = 610.7\times \text{exp}\left(
\frac{17.38 (T - 273.15)}{239 + (T - 273.15)}
\right)
$$
Where $T$ is the temperature in degrees K.
Vapor pressure deficit (VPD) can be calculated a variety of ways but is always defined as the difference between SVP and the actual vapor pressure (AVP); hence, MOD16 calculates VPD by first calculating the AVP, after Gates (1980):
$$
\text{AVP} = \frac{\text{QV10M}\times \text{P}}{0.622 + 0.379\times \text{QV10M}}
$$
Where QV10M is the water vapor mixing ratio at 10-meter height (units: kg per kg) and P is the surface pressure (units: Pa). Whereas surface pressure elsewhere in the MOD16 algorithm is calculated based on elevation, in the AVP calculation, above, $P$ is derived from a gridded climate re-analysis dataset.
Finally, VPD is the difference between SVP and AVP:
$$
\text{VPD} = \text{SVP} - \text{AVP}
$$
Relative humidity (RH) can then be calculated as the difference between VPD and SVP, normalized by the SVP:
$$
\text{RH} = 100\times \frac{\text{SVP} - \text{VPD}}{\text{SVP}}
$$
After Fisher et al. (2008), we calculate the wetness of the evaporating surface, or fraction that has standing water, $F_{\text{wet}}$, based on the relative humidity:
- $F_{\text{wet}} = 0$ iff RH < 70%
- Otherwise, $F_{\text{wet}} = (\text{RH}/100)^4$
The latent heat of vaporization, $\lambda$ (units: Joules per kilogram), is a key term that quantifies the amount of energy required to vaporize a kilogram of water, based on the current temperature of the water:
$$
\lambda = (2.501 - 0.002361\times (T + 273.15))\times 10^6
$$
The psychrometric constant, which relates the vapor pressure of air to its temperature, is calculated:
$$
\gamma = \frac{C_p \times P}{\lambda\times 0.622}
$$
This is the approach used by the FAO but it is also described by Maidment (1969). $C_p = 1013$ (J per kilogram per Kelvin) is the specific heat capacity of air, P is the air pressure, and 0.622 is the ratio of molecular weights, water vapor to dry air. Values for $C_p$ and water vapor-dry air ratio are taken from Monteith & Unswoth (2001).
The slope of the saturation vapor pressure curve, $s$ (units: Pa per degree K), which describes the relationship between SVP and temperature, must also be determined:
$$
s = \frac{17.38\times 239\times \text{SVP}}{(239 + (T - 273.15))^2}
$$
Note that this formula comes from the MOD16 source code and cannot be further attributed. An alternative would be the FAO formula (Equation 13).
Air density must also be calculated; we use the NIST simplified air density formula with buoyancy correction (NPL 2021):
$$
\rho = \frac{(0.34844\times P) - \text{RH}(0.00252\times (T - 273.15)) - 0.020582}{T}
$$
Where $P$ is air pressure in millibars; RH should be expressed in percentage terms.
In MODIS Collection 6.1, MOD16 used air pressure as given by the surface meteorology dataset used (e.g., as a field in the re-analysis dataset). Going forward, MOD16 will instead calculate air pressure as a function of elevation:
$$
P_a = P_{\text{std}}\times \left(
1 + \ell z T_{\text{std}}^{-1}
\right)^{5.256}
$$
Where $\ell$ is the standard temperature lapse rate (-0.0065 deg K per meter), $z$ is the elevation in meters, and $P_{\text{std}}$, $T_{\text{std}}$ are the standard pressure (101325 Pa) and temperature (288.15 deg K) at sea level. The exponent 5.256 is a pre-determined quantity based on physical constants and derived from the discussion on atmospheric statics in Iribane & Godson (1981).
Evaporation from Wet Canopy
Evaporation from wet canopy occurs when a portion of the surface area under investigation is saturated with water; it consists of precipitated water intercepted by the leaves of trees and other plants. As with all the components of ET, it is calculated separately for daytime and nighttime inputs. First, net radiation to the canopy is calculated as:
$$
A_{\text{canopy}} = F_C\times A
$$
The movement of water vapor from the surface to the atmosphere is analogized to an electrical circuit (Zhang et al. 2016). Therefore, the next step involves calculating the resistances to the flow of water vapor. The resistance to radiative heat transfer through the air, $r_R$, is given as a function of temperature ($T$, degrees K) and air density ($\rho$):
$$
r_R = \frac{\rho C_p}{4 \sigma T^3}
$$
Where $\sigma$ is the Stefan-Boltzmann constant.
The resistance of wet canopy to sensible heat is given in terms of the leaf area index (LAI), $F_{\text{wet}}$, and the leaf conductance to sensible heat (per unit LAI), $g_{SH}$, which is a free parameter:
$$
r_{SH} = \frac{1}{g_{SH}\times \text{LAI}\times F_{\text{wet}}}
$$
Similarly, the resistance of leaf surfaces in wet canopy to evaporated water, $r_{WV}$, is given in terms of the leaf conductance to evaporated water (per unit LAI), $g_{WV}$, a free parameter:
$$
r_{WV} = \frac{1}{g_{WV}\times \text{LAI}\times F_{\text{wet}}}
$$
And, finally, the aerodynamic resistance to evaporated water on the wet canopy surface, $r_{\text{wet}}$, is given by combining the resistances $r_R$ and $r_{SH}$ in parallel, because heat (of the wet canopy surface) can be lost through either channel:
$$
r_{\text{wet}} = \frac{r_{SH}\times r_R}{r_{SH} + r_R}
$$
We now have all the quantities necessary to calculate the wet canopy evaporation flux:
$$
\lambda E_{\text{canopy}} = F_{\text{wet}} \frac{
s A_{\text{canopy}} + \rho C_p [\text{VPD}] (F_c / r_{\text{wet}})
}{s + (P_a C_p r_{WV})(0.622 \lambda r_{\text{wet}})^{-1}}
$$